SEMI-AUTOMATIC BIOCHEMICAL ANALYZER MODEL
BA-2000II
* large LCD display
* Internal printer, save the data even after power-off
* analysis mode: ABS, end point, two points, continuous
monitoring, linear and non-linear calibration
* open programming, use universal reagents
* automatic monitoring the whole course, automatic alarm,
automatic display A-T curve or A-C curve. Save linear and non-linear curve
at same time.
* If combined with PC, it can use the lab managing system
and print reports, quality controlling curves.
Specification:
-
light system: quartz halogen lamp 12v / 20w
-
wave length: interference filter: 340nm, 405nm, 492nm, 510nm, 546nm,
578nm, 630nm
-
semi-bandwidth: 8-12nm
-
ABS limit: 0.000-2.500ABS
-
Differentiate rate: 0.001ABS
-
Wave drift: 0.002A / h
-
Colorimeter system: stainless steel / quartz flowing 32ul
-
Temp: room temp, 25ºC,
30ºC,
37ºC
interchangeable, accuracy: 0.1ºC
-
Inter-cross pollution: <2.0%
-
Scattering light: <1% (340nm)
-
Sample volume: 200ul –2000ul adjustable
-
Analysis modes: ABS, end point, two-point, continuous monitoring
-
Output: RS232, can be connected to standard PC
-
Working condition: temp: 15ºC
- 30ºC
Humidity: 85% R.H
- Power: AC220V, 50 / 60Hz
BA-400
SEMI-AUTO BIOCHEMICAL ANALYZER
FEATURE:
* Strong interference filters, resistant to humidity and
high temperature, long life, no drift of the central wavelength
* Titanium alloy flowing cell with more excellent
precision of temperature control and measuring repeatability of
absorbance. It reduces the intercross pollution.
* Quality control system can show all the statistic
results and quality control charts within 31 days
* Auto-conversion of wavelength, change or expand
programs, 200 programs editable, parameters can be changed at any time and
saved permanently.
* Print report according to the test items or patient No.
The data won’t be lost during power failure.
* Supervise the whole reaction process, and print ABS-time
curve
* Large LCD display. Inter-dialogue type. The system is
micro-computer controlled.
* Optical
system: complete sealed, dust and humidity resistant.
* Measurement modes: speed rate, two-point, end-point,
double-wavelength, absorbance, non-linear and continuous supervising
Specifications:
* Measuring
wavelength: 340, (380) 405, 450, 492, 510, 546, 578, 620 (630) nm 8
filters and 2 optional blank positions.
* Stability:
absorbance changed<=0.002 within 20min
* Intercross
Pollution: <=2%
* Spectrum
bandwidth: <8nm
*
Repetition: <=1%
*
Colorimetry system: light path 10mm, 32ul titanium alloy flowing cell.
* ABS:
-0.3-3Abs
* Sample
Volume: 200-2000ul adjustable
*
Resolution: 0.001Abs
* Temp
control: 25ºC,
30ºC,
37ºC+0.1ºC
* Computer
interface: RS-232
* Light
system: 12V, 20W halogen tungsten lamp
* Power
supply: 220V+15%, 50-60Hz
BA-200
SEMI-AUTO BIOCHEMICAL ANALYZER
Features:
l
Concave
grating is used, better than plane grating.
Auto controlled
l
Measurement
modes: speed rate, two points, end point, absorbance and single or double
wavelength.
l
There are 200
common-used biochemical items stored inside. The programs are open
l
Many kinds of
reagents can be used.
l
Automatically
print report, store data, adjust wavelength and real time display.
l
Power-off
protection, more than 3000 measurement reports of the biochemical items
can be stored.
l
Display the
standard curve of non-linear end-point method
BA-EⅡ
BIOCHEMICAL ANALYZER Economic type Features:
l
Micro-computer control, 64
x 240 LCD display
l
Auto print, store and real
time display. Can store 3000 test results and 31 days quality control
data.
l
Automatically print the
general report of any item or sample and total items or samples, Time
screen display, clock setup, mistake alarm
l
Measurement modes: linear
or non-linear end point, absorbance and single or double wavelength.
l
More than 200 test items
and open programs. Wide range of reagent can be used.
|
||||||