GM-1 Glucose Meter

INTRODUCTION

Self-monitoring of blood glucose is an only method to determine people’s glucose level in home. Many diabetics for their treatment medicine diet and blood glucose control currently use the method.

Simply by touching a drop of the tip of  test strip, the reaction chemicals on the tip area is automatically reacted with the glucose level. No wiping or blotting of the test strip is necessary, it is a simple and practical system for the daily monitoring of your blood glucose level.

TEST PROCEDURE 

Basic instructions for the use of the Glucose Mter are described below and detail directions see the respective Operating Manual. 

NOTE

-Check that the expiration date for the test strip has not lapsed.

-Wash your hands wish soap and warm water. Rinse and dry then thoroughly. Perspiration, dirt or water remained on the finger may cause incorrect results.

STARTUP THE TEST METER

Turn on the meter, the meter shows you a last blood data and code number, check the code number carefully on the strip vial, if its code number does not match the number indicated on the display, press the on/off button until get right code.

APPLY BLOOD

Collect a drop of blood by using a lancing device. Apply the drop of blood on the tip reaction area. The test strip will draw blood into the reaction area and test meter starts measuring. Simultaneously, the display will indicate the remaining time. You must apply the drop of blood to the test strip while “rdy” is displayed.

NOTE

-If the test strip is not filled with blood sufficiently, an incorrect test result may obtain. See the figure in Manual for the required blood volume and perform the test properly.

-Be sure to apply a drop of blood to the tip reaction area of the test strip.

Otherwise measurement will not begin.

PERFORMANCE AND CHARACTERISTICS

MEASUREMENT RANGE: 40-500mg/dl(2.22-27.78mmol/l)

SPECIFICATIONS

The glucose meter test strip reacts specially with β-D-glucose at the detection sensitivity of 40mg/dl (2.22-27.78mmol/l)

Blood: 20ul

Time:20s

Power consumption: >=1000 tests

The test strips can be available in test strip vial for one year but after first opening the rest strips should be finished using in 2 months.

Net weight: 44g

GM-2 Glucose Meter

         

Specifications:

Application: full blood

Range: 40-600mg/dl2.22-33.3mmol/L

Time:20s

Capacity:60 samples/hour

Storage: the test trip can be stored for 15 months in a sealed package with temperature 5-40 degrees

Power supply: three No.7 batteries

Dimension: 115X62X18mm

Weight:100g